Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERS RUN
Address3200 SELWYN FARMS LANE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/17/2017
Final Score @ Grade
26
General CommentsObserved vac alert system installed but not operational. Pool has 2 main drains. Note: Pool hours of operation are 8am-8pm; no night time swimming due to no lights on pool deck. Wall damage observed inside pump room.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed pool wall and floor with debris.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmer baskets with floating debris. Observed one broken skimmer basket.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed rope length greater than 50Ft. Rope length required = 50Ft. Cut to 50ft during inspection by pool operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed 2 areas between vertical members of fence > 4". Corrected to 4" during inspection by pool operator. Observed one gate not self -closing self latching properly. Repaired during inspection to self-close and self-latch.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed lawn chairs < 6Ft from pool deck. Chairs moved to provide 6ft deck clearance.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter stuck. Repaired during inspection.