Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRED LION HOTEL
Address212 W WOODLAWN RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/6/2015
Final Score @ Grade
24
General CommentsPool Permit Issued. Intent to Suspend issued for record keeping and wall depth marker at 3 ft. Note: Wall extended to equalizers. Equalizers approved. Paramount SDX Retro approved on main drains with requirement 3 hp pump is used as main pump. Other pump must remain off. 6 hour turnover met with current pump and 40,000 gallon pool. Note: Contrasting color band (tile) >1" from edge of step. Repair before permit will be issued for 2016 season.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyanuric acid readings or main drain checks recorded. Record chlorine, main drain check and pH daily. Total alkalinity and cyanuric acid weekly. Intent to Suspend issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir stuck in skimmer. Keep fully operational.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Deck depth marker installed. No wall depth marker at 3 ft. Provide. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder handrail 9" from wall. Maintain between 3" and 6" between ladder handrail and wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >4" between fence and building wall. Maintain 4" less between post and wall.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No hose bib or floor drain in pump room. Originally constructed without.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash direct plumbed. Provide air gap. Originally constructed without.