3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.
Observed 6.8 pH. Operator corrected to 7.3. No permit action. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Both end caps missing on ladder. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Liquid chemicals in pump room. Dry chemicals stored in separate shed. No clearance around piping. Original construction.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting
.2533(c) Valves and controls shall be accessible to the pool operator at all times.
Maintain 3 ft. clear walking space in pump room.
.2533(b) Provide sufficient lighting in pump room.
Observed no light in the pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap.
Observed no air gap for backwash. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2526(h) Shower(s) shall be provided.
Observed no working shower. Manager stated that it was removed years ago. |