Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHIGHLAND CREEK-PROSPERITY
Address5710 FAIRVISTA DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/17/2024
Final Score @ Grade
14
General CommentsNO NIGHT SWIMMING. Field verified: New Pump Jandy JCP Serie, JCP05-3AT-S, 5 hp pump Flow meter must be operable. Confirm the measurements provided measures at least 20 on the pipe before the flow meter and at least 8” on pipe after the flow meter back to the returns. Flow should read greater than 335 gpm. Piping Main drain line is a 6” line; Skimmer and return are 4” these are measured with pipe coming out of the pump room floor. (2) Aquastar VGBA-2017 1216xxx drain covers (11) skimmers with EQ lines plugged (4) Pentair TR140C filters (20) returns either on wall or floor.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 2 missing weirs. CDI
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed openings under fence > 4”.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Provide a vacuum cap or self-closing cap. No vacuum cap on vacuum line. CDI
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Need directional flow markings on piping.