Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHEATHSTEAD 1 ADULT
Address6140 HEATH RIDGE COURT
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/13/2021
Final Score @ Grade
16
General CommentsNo night swimming permitted. General Comment Ensure guard room is accessible.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed pool floor floor with some leaves / debris.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed greater than 4" from grade to bottom horizontal on perimeter barrier and measuring 5 1/2" 6 inches in areas under black fencing to bottom horizontal. Observed damage to chainlink fence measuring 6" wide. .2537(b) All gates and doors shall be self-closing, self-latching. Entry gate on right side of pool did not self-close/ self-latch. CDI, operator able to adjust gate so that it was self-closing / self-latching. - If fencing is replaced it must meet .2528 with inspection completed by code enforcement.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Oberved flow meter stuck. CDI, corrected on-site.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed sodium chloride and sodium bicarbonate stored on ground in chemical room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.