5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool records shall be kept daily. Cl, pH, main drain = check daily. Alkalinity and Cyanuric Acid = check weekly. No records on site. Intent to suspend issued. Correct within 30 days. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir is missing from skimmer. Replace missing weir. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy length should be only 30 ft. Observed at roughly 50 ft. Operator cut to 30 ft during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Upon entry into the pool, I observed both gates locked open. Operator removed locks and corrected one gate so that it was self-closing, self-latching. The other gate was locked closed and will not be utilized. This gate shall remain locked at all times. If used, it must meet all requirements including no 1/2 inch gaps within 18 inches of latch.
Observed opening under one gate to be 4.75 inches. Pool was built in 1986 so the opening must be no greater than 4 inches. Correction required within 30 days. Intent to Suspend permit issued.
Note: Distance between slats of gate is 5 inches. |