Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDOUBLETREE SUITES BY HILTON
Address6300 CARNEGIE BLVD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2026
Final Score @ Grade
38
General CommentsFeature is missing several tiles, items must be replaced prior to permit issuance of 2027 pool season. EHS recommend to re-paint etched “no diving” and depth markers with a contrasting color. Re-inspection fee required. Call main office at 980-314-1620 once all 4 and 6 point demerits are corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmer baskets. CPO dumped during inspection
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 missing inlet covers and 1 inlet cover missing the direction flow piece. Permit denied
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. Observed body hook mixed in with pool cleaning equipment on top of brick wall. CPO moved body hook to hooks on front of brick wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inch gap under maintenance gate in back corner. Pool was built in 1984 .2537(b) All gates and doors shall be self-closing, self-latching. Observed main gate latch not catching consistently when gate is used. Permit denied.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed “warning no lifeguard on duty” signage faded. Permit denied.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed signage at emergency with address stating “Carnegie bv” 911 operator stated they have Morrison bv on file. Google Maps is showing 6300 Carnegie bv and 6300 Morrison bv are the same place where the pool is located. CPO changed address on signage to match 911.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed both flow meters not operational. Permit denied. Observed heavy leaking in pump room underneath pipes.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemicals stored in pump room. Pool was built in 1984
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping in pump room without arrows indicating direct of flow.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Unable to locate hose bib for restrooms.