Premises Information

Return to Inspections
NameGREENBRYRE
Address3541 SPANISH QUARTER CIRCLE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/17/2025
Final Score @ Grade
24
General CommentsNO NIGHT SWIMMING. NOTE: Gate swings towards pool due to ramp (Pool is pre-2010) If changes to fencing or decking are made gate will need to be corrected. PERMIT RESTRICTION: TABLES OR CHAIRS MUST BE PLACED OVERTOP BOTH SETS OF ELECTRICAL PIPING LOCATED ON DECK AT ALL TIMES TO PREVENT TRIP HAZARDS.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit with expired reagents. CPO provided test kits with new reagents.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmer basket. CPO dumped skimmer basket.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder closest to fence loose. Tighten ladder.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding required length. CPO cut rope to required length during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 2 sets of electrical piping sticking up from deck. Piping was approximately 12 inches tall. CPO placed tables over electrical piping to prevent trip hazard. See general comment box for added permit restriction.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed no “adults should not swim alone” signage. CPO added signage during inspection.