Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFRANCISCAN TERRACE CONDOMINIUM
Address4751 HEDGEMORE DR
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/21/2014
Final Score @ Grade
16
General Comments#7 Strip below coping in 2 areas damaged & bolts/nails used to secure. GC #10 Break point color band chipped. **re-paint before next season. GC #17 Deck chipped near front gate. Notes: old pool -has hopper bottom now prohibited on new construction. (.2516A) -safety rope hook anchors not recess. (.2515f) -no apparent back flow prevention device observed on water line that connects directly to circulation system piping. -per homeowner's association president - pool closes @ 7:00pm. Intent to suspend issued for #9, #16, & #19.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 2 deck depth markers spaced ~27' apart. **Maximum spacing is 25'. Some pool wall depth markers chipped. **re-paint. Intent to suspend.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Club house door will not self-latch . ****correct. Intent to suspend.
19 4 Premises: signs prohibit glass containers or pets in pool area No No No Incorrect pool rules sign posted (South Carolina). **correct/replace. Intent to suspend.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water @ lavatories 113F. **Maximum of 110F allowed.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No back flow prevention on hose bibs in equipment/chemical room. **install vacuum breakers on hose bibs.