16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed a ground level window inside the gym, with access to the pool, opening fully. The window was 25” from the ground. CDI-PIC added screws into the window frame and window can only open 3”. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed a large gap between the deck tile and the pool tile, larger than 1/2 inch, possible trip hazard. CDI-PIC put in polymeric sand. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
Observed pool sign with lettering only at 3/4”. CDI-PIC added new sign with 1” lettering. |