3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.
PH RECORDED AT 6.8. CDI- SODA ASH ADDED, INCREASED TO 7.2 |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions.
LADDERS NOT SECURE. CDI- SECURED |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
BODY HOOK NOT SECURE. SECURED WITH SCREWS |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool.
ONE GATE SWUNG INTO POOL. CDI- HINGES MOVED TO MAKE GATE SWING AWAY FROM POOL |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels.
NO MARKINGS ON PIPE. CDI- PIPES MARKED WITH FLOW DIRECTION |