16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Brick barrier with metal fencing on top is 36” from ground creating a foothold.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). In some sections around the pool fencing at the bottom is greater than 4”. Sheet of metal fencing material were placed around bottom to close gaps.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Areas of fence measure greater than 4”. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Repair cracked areas of deck on right side.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazard on deck leading tp patio area on right side of pool. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(6) Provide sufficient lighting in chemical storage room. No lighting provided in chemical room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. No air gap provided for backflow |