Premises Information

Return to Inspections
NameFIRETHORNE CONDOMINIUMS
Address5701 AMITY SPRINGS DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2018
Final Score @ Grade
20
General CommentsPDSC form verified. Pump model # was missing. It appears the same as the model spec sheet. HP of motor was 3HP and pump is listed as a 2HP.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed large amounts of debris on pool floor.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. Two no diving markers were 40 feet apart as the crow flies. NO DIVING was added to pool deck between the two.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Brick barrier with metal fencing on top is 36" from ground creating a foothold. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). In some sections around the pool the fencing opening at the bottom is greater than 4". Sheets of metal fencing material were placed around the bottom to close gap. .2528(b) Maintain between 30" or greater between bottom horizontal and next horizontal on fence and/or gate (pre-May 2010). Fencing on top of brick wall has only 19" between horizontals. Distance between verticals shall be no greater than 4". Distance between verticals at this pool is 6-7". Approved by Chris Sells due to pool build of 1989.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Strainer lid broke during inspection so strainer cannot be emptied and water is shooting out.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(6) Provide sufficient lighting in chemical storage room. Light in pump/chemical room is not functioning. .2533(3) Provide continuous forced ventilation or cross ventilation in pump room. No cross or forced ventilation in pump/chemical room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Piping and valves were relabeled during inspection.