Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFALCONBRIDGE CONDOMINIUMS
Address8524 PINE THICKET COURT
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/20/2026
Final Score @ Grade
20
General CommentsNIGHT SWIMMING NOT PERMITTED. DEPTH OF POOL EXCEEDS 5FT; DASHBOARD STATES POOL DOES NOT REQUIRE LIFEGUARD ON DUTY; POOL HAS REQUIRED NO LIFEGUARD SIGNS PRESENT. FLOW METER MUST REMAIN OPERABLE. FLOW MUST BE MAINTAINED AT 104GPM DUE TO TURNOVER, NEVER TO EXCEED 119GPM DUE TO SUCTION HAZARD. MAIN DRAIN COVERS EXPIRE:10/1/2030 EQUALIZER COVERS EXPIRE:10/1/2030

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Per permit conditions flow meter must remain operable at maintained at 104GPM due to turnover, never to exceed 119GPM due to suction hazard. EHS observed flow at 80GPM at pump set to 3150. PDSC form stated pump should be set to 3450. CDI - CPO adjusted rpm to 3450, EHS observed flow at 104GPM prior to end of inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. EHS observed debris present in skimmer baskets. CDI - CPO removed debris.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). EHS observed opening under gate at 4”. Pool was constructed pre-2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. EHS observed deck obstructed by pool furniture not provided a clear 6ft of walking space. CDI - CPO moved furniture back to provide 6ft walking space.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. EHS observed burn damage present in women’s restroom. Black residue present on walls and fixtures.