|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Per permit conditions related to approved PDSC form, pump shall be run at 3300RPM ,and flow meter must remain operable with flow at 104 gpm for turnover and flow restriction of return pump sizing. However, flow meter observed at 95gpm and pump running at 3310 GPM. - CDI - CPO corrected pump setting to 3300RPM and flow meter observed to be correcting towards 104gpm as pool water level increases. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Water level shall be maintained to assure skimmers are operable. - Observed water level slightly below skimmers upon arrival. - CDI - CPO began adding water to pool to allow skimmers to operate properly. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. - Observed no diving painted markers to be severely deteriorated such that some letters were no longer legible or contrasting. - CDI - CPO repainted markers to allow all letters to be legible and properly contrasting. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope for ring buoy to be longer than 38ft. - CDI - CPO corrected rope length to 38ft. |