Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOASIS AT REGAL OAKS, THE
Address6701 ENGLISH HILLS DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/4/2023
Final Score @ Grade
18
General CommentsPermit denied today due to bonding wire not attached to motor on pump in equipment room. Inspection from MC code enforcement required. Please provide electrical permit number. Senior Chris Sells: (704)-576-8678 Email Christopher.Sells@mecklenburgcountync.gov if you have any questions or concerns.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed one missing wier in skimmer basket. CDI: Wier replaced.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope on buoy to be greater than the 30ft requirement for this pool. CDI: rope cut to 30 ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed windows opening greater than 4 inches without audible alarm.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Observed return fitting on vacuum line. CDI: CPO installed a threaded vacuum cap cover. .2518(h) Provide approved pump in good repair. Observed bonding wire not connected to pool pump.