16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed fence peeled back in one section at top of hill
greater than 4". CDI - Maintenance repaired fence during inspection. -4- |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed 5'9" clearance near deck chairs on the pool deck.
CDI - Operator moved chairs back to greater than 8'.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed holes on deck that appear to be for a ladder at 2.5". CDI - Operator placed plugs in the holes during inspection. -4- |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed no sign stating exact wording for adult swimming as listed
in pool rules. CDI - Operator posted sign with exact wording during inspection. -4- |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Observed filter backwash piping below the floor plane of the sump.
CDI - Operator shortened pipe during inspection. -2- |