NameCOMFORT INN
Address5822 WESTPARK DR
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/26/2023
Final Score @ Grade
28
General CommentsInspection conducted with maintenance personnel, Joe. PDSC information and permit restrictions verified. Permit denied. Items that will hold up permit: - .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Non-collapsible pole unavailable for body hook (colored blue). - .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed unapproved, residential ring buoy onsite. - .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring > 26 ft. - .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no lifeguard on duty warning signs measuring < 4" in lettering. - .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed inoperable emergency phone at pool deck. - .2518(g) Keep flow meter operational. Observed inoperable flow meter during inspection. ***Observed chlorine to be over 10. Recommend to reduce chlorine to avoid skin irritation. Once non-compliant items have been corrected, please contact Environmental Health at 980-314-1620 to submit re-inspection fee.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed debris on floor of pool. -4-
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed loose ladder at 3 ft depth marker. -2-
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. No pole available for body hook. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed unapproved, residential ring buoy. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring > 26 ft. -6-
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no light guard on duty warning signs measuring < 4" in lettering. -4-
22 6 Premises: emergency telephone provided No No No .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed inoperable emergency phone at pool deck. -6-
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed inoperable flow meter during inspection. -4-
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Post a shower sign visible upon entrance to the pool. No shower signs available at entrance of pool. -2-