Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROWN POINT TOWNHOMES
Address7422 PEBBLESTONE DR
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/30/2022
Final Score @ Grade
34
General CommentsRepair items and call main office at (980) 314-1620 to pay $100 reinspection fee. To reschedule a reinspection tomorrow if ready, call Rachel Santimaw at (704) 280-2807. If reinspection is requested July 5th or later, call John Compton at (704) 621-2294.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed pool with 0ppm chlorine.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one floor return fitting missing in shallow end.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed stryrofoam ring buoy that is not US coast guard approved present. Observed rope attached to ring buoy 47ft. Rope is required to be 50ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(c) New fencing installed must be in compliance with .2528 Fences. Current fence does not meet current code however fencing was constructed pre-2010. If fence is replaced in future it must meet current requirements.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed warning signs in place with 3” lettering.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Pool has a Kings III system. When routed to 911, no phone number or address are listed with 911 operator.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed main drain and skimmer pipes not labeled.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed backwash line dish charged with no air gap.