Address6000 DELTA CROSSING LANE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/25/2023
Final Score @ Grade
8
General CommentsEHS observed 2 doors leading from the front office to the pool deck which are used for the gym. The 2 doors have locks which are 36 inches from the floor and can be easily unlocked by children. EHS recommended locking the door from the pool deck to the restrooms which is in between the gym. This latch is 58 inches from the floor. EHS recommended locking this door until an audible alarm can be installed on door leading from pool deck to restrooms.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b)(3)(B) The leading edge of handrails facilitating stairs and pool entry/exit shall be no more than 18 inches horizontally from the vertical plane of the bottom riser. Distance from leading edge of handrail to vertical plane of bottom riser measured 27 inches. Replace handrail during next planned renovation with a longer handrail to ensure distance from leading edge of handrail is 18 inches or less from vertical plane of bottom riser.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Audible alarm for door leading from office to pool deck was turned off. Pool operator turned audible alarm on. Keep audible alarm turned on.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. Door leading to restrooms is kept locked until an audible alarm can be installed to prevent children from entering pool deck unattended.