Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDAVIS LAKE SWIM & TENNIS CLUB
Address9000 DAVIS LAKE PKWY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/15/2018
Final Score @ Grade
32
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfecant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no record sheets. CDI sheets provided. Repeat.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed pool with debris but still able to see main drains.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets and equalizer covers soiled with debris. Observed soda ash placed in skimmers to change chemistry of the pool. Repeat.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed handrails for laaders that were loose and one that came off the hinges. Repeat.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. Pool will have a lifegaurd and two body hooks available just missing a ring buoy. CDI ring buoy provided with 54" rope length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Mesh shall not exceed 2.25" square. Observed chain link that has been stretched over 2.25". Pool is pre-2010 meshing will be repaired before opening. .2528(b) Maintain between 30" or greater between bottom horizontal and next horizontal on fence and/or gate (pre-May 2010). Observed flower pots next to gates creating a foothold. CDI pots relocated.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq ft). Observed construction occuring at pool and less than 8 ft clearance available. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.Observed holes in ground by diving board and skimmer that was 2" wide. CDI holes filled. .2537(2) Decks shall be kept in good repair. Observed deck cracked and and concreter pieces on surface of pool. Pool deck is in need of resurfacing.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. Observed no spare basket for pump. CDI basket provided.