NameDAVIS LAKE SWIM & TENNIS CLUB
Address9000 DAVIS LAKE PKWY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/28/2017
Final Score @ Grade
32
General Comments6. Slide drain covers not approved, submit revised PDSC form by Monday, July 3 or permit will be pulled 18. ITS issued for incorrect sign verbage, missing weirs

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Record total alkalinity & cyanuric acid level 1 x week, record daily maintenance, chemical additions - corrected during inspection
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Replace missing weirs, keep baskets free of debris
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Tighten loose handrails
18 4 Premises: lifeguards present or warning signs posted No No No Correct missing sign verbage
22 6 Premises: emergency telephone provided No No No Sign information not located close to phone-corrected during inspection
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working-corrected during inspection
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet beside slide pump - pump is leaking
27 2 Equipment room: filter backwash discharged through an air gap No No No 2" air gap required on back wash line
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Mirrors to be of shatterproof construction
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Back flow preventer required on hose bib