Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCRESWICK CONDOMINIUMS
Address2516 STRADBROOK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2026
Final Score @ Grade
8
General CommentsNo night swimming Expired reagent #2. Replace Verified at pool: Permit Restriction: Flow meter must remain operable. Flow required at 85 gpm to 100 gpm to meet turnover and flow restriction of the filter. Flow greater than 125 gpm exceeds the main drains. Suction Hazard. 5% flow meter needed. New Pump Hayward TristarVS 950 SP32950VSP, 2.7 THP Blue white flow meter reading the above range on flow. Main drain, skimmer and return line all 2” pipe 2008 Hayward WG1048E drain covers. (3) skimmers with (3) Aquastar 2017 6HPHAxxx eq line covers. Triton TR100 filter 6 returns located on either the floor or the wall.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Observed handrail loose. CDI-tightened
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 missing wall return fittings. CDI-replaced
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. Observed mirrors shatterproof .2526(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper .2526(m) Keep restrooms and fixtures clean and in good repair. Observed bathrooms need cleaning