Premises: emergency telephone provided |
No |
No
|
No |
.2530 (f) Emergency phone shall be correctly identified by address and phone number when calling 911 Emergency operator. Observed 911 operator identify the phone number as 704-532-3818 instead of the posted 704-568-5910. CDI - PIC placed label with correct phone number over the incorrect number posted. -6- |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533 (g) Backflow preventer shall be installed on hose within 50 feet of equipment room. Observed no backflow preventer on hose bib to the right of entrance. Install backflow preventer. -2- |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518 (d) Exposed pipes or valves shall be labeled. Observed no labels on the exposed piping in the equipment room. CDI - PIC labeled flow and circulating system parts on the pipes during the inspection today. -2- |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2526 (a) Shower sign shall be posted. Observed missing sign with sign holder still in place. CDI - PIC purchased one and posted during the inspection. -2- |