Premises Information

Return to Inspections
NamePARK 2300
Address2300 VILLAGE LAKE DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/11/2014
Final Score @ Grade
28
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Test and document water quality per requirements. Chlorine and pH shall be tested and main drain checked daily and appropriately logged. Alkalinity and cyanuric acid shall be checked and logged weekly. General pool maintenance performed should be noted. No record of testing or drain checks. ITS issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Maintain skimmer box weirs. No weirs in skimmer boxes. ITS issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No No diving and depth markers shall meet requirements. Observed area of pool less than 5 ft where no diving signs and depth markers do not meet requirements. Gave written copy of signage requirements. ITS issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Maintain required gates and doors into pool inclosure. Observed unlocked door from lobby opening into pool enclosure without key lock or audible door open notification. Gave instruction. ITS issued.
22 6 Premises: emergency telephone provided No No No Maintain emergency phone fully audible. Kings III unit is being used and address and phone # are correct but when put through to 911 the operator is barely audible and connection has static on both ends. Unit is working and is easily heard. Gave instruction to contact Kings III to see if direct 911 connection can be made louder and static free. No IS needed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Maintain flow meters functioning properly. Observed stuck flow meter. Gave instruction . ITS issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Shatterproof mirrors required in restrooms. Observed glass mirror. Gave instruction.