Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTOWNES AT UNIVERSITY APTS
Address336 BLACKHAWK ROAD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/20/2020
Final Score @ Grade
10
General CommentsInspection conducted with Darius Holmes. Due to COVID-19 precautions, inspection was not signed by the operator. No sign on bathroom door. Recommend adding signage to restrooms so that bathers know it's a public restroom. One screw in body hook. Recommend using two screws. Recommend installing grating for overflow pipe. Green algae starting to grow on steps and pool walls. Maintain pool free of algae. Some depth marker stickers starting to peel. Maintain stickers in place. Permit issued. No Night Swimming “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow preventor on hose bibb on the pool deck. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drain in bathroom. .2526(c) Floor drains shall be provided in restrooms.