12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One inlet fitting plugged, had a wire nut in it. Removed by operator. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope too long. Provide 37.5 ft throw rope. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pump basket full of leaves. Not functioning properly. Cleaned by operator.
No spare pump basket. .2518(e) Provide a spare basket for pump.
Flow meter installed near an elbow, there should be enough straight piping to install correctly. .2518(g) Install flow meter on return line per manufacturer instructions. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light burned out. .2533(b) Provide sufficient lighting in pump room. Corrected by operator.
No floor drain in pump room. .2533(d) Provide drain in pump room floor.
Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. Corrected by operator. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
.2626(c) Floor drains shall be provided in restrooms.
.2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |