Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRED ROOF INN LAKE NORMAN
Address20740 TORRENCE CHAPEL ROAD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/7/2026
Final Score @ Grade
20
General CommentsPermit denied due to: .2530(f) Failure to provide a working emergency phone. .2535(1) Failure to Maintain pH at 7.2 to 7.8. .2535(4) Maintain chlorine at least 1.0 ppm. Pool requires reinspection prior to opening. Call Environmental Health front office when ready to request a reinspection. $100 fee required. 980-314-1620 Pool is approved for Salt as primary chlorination. 36” foot holds exist on the sides of the fence. (Pre-2010)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed 0ppm chlorine during inspection.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed a pH of 8.4 during inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Phone could not dial 911 during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. .2534(6) Provide sufficient lighting in chemical storage room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed no working lights and no cross ventilation in the pump/chemical room.