5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
CPO not present at time of inspection. CPO shall maintain daily site visits to maintain the pool. Permit Item.
Provide record keeping for total alkalinity and cyanuric acid weekly. Provide record keeping for main drains checks daily. Permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Screw protruding from light >1/2". Repair screw in wall. Permit Item.
Some damage to the pool paint. Continue to monitor. May require repair if worsens. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers on pool wall missing "ft"/worn off. Provide ft or feet on pool wall on all depth markers. Permit Item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder rungs 8 1/2" from pool wall. Maintain 3" to 6" from ladder rung to wall. Original construction. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
USCG approved ring buoy with grab rope degraded and damaged. Replace with USCG approved ring buoy. If rope replaced, provide 23 ft. rope. Old rope still ok. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
REPEAT .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Gates observed to swing into pool area per fire egress from main building.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Openings around pool fencing observed greater than 4 inches in some areas.
<45" between horizontals on pool barrier. Pool built pre-May2010.
One of two entrances kept locked; however, when unlocked, gate does not self-latch. Permanently disable if fire/building ok or repair gate to self-close, self-latch. Permit Item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Warning No Lifeguard on Duty not large enough lettering. Provide Warning No Lifeguard on Duty in 4" lettering. Permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Small leak at air relief valve on filter. Repair leak. Does not warrant permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light burnt out in pump room. Repair light. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No check valve or backflow prevention device on hose bib in pump room. Original construction. Provide ASSE approved check valve and backflow prevention device. |