Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRED ROOF INN LAKE NORMAN
Address20740 TORRENCE CHAPEL ROAD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/12/2019
Final Score @ Grade
14
General Comments5) Records not being consistently kept since the pool has been closed all summer. .2535(11) Provide record keeping including daily records of disinfecant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain CYA at no more than 100 ppm. 16) Gates swing into the pool area. Recommend that they swing away from the pool area provided that the hallway is not a fire egress. Check with the Fire Marshall and go with their recommendation. Permit issued with the following conditions: No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No 16) Fencing does not meet current rules. Appears to be pre-2010. Gaps as large as 5" through the fence, fence as short as 36". Provide fencig at least 48" high with no gaps greater than 4" through the fence. 16) Gates swing into the pool. Appear to be for fire egress. Recommend checking with fire marshall. Gates should swing away from the pool.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter reads more than the filter and multiport are rated for. Operator states it's a new flow meter. .2518(g) Install flow meter on return line per manufacturer instructions. Flow meter shall read within 10% of true flow.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. .2626(i) Water in restrooms shall not exceed 110 F.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. .2626(c) Floor drains shall be provided in restrooms.