Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRED ROOF INN
Address5111 EQUIPMENT DRIVE
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/24/2013
Final Score @ Grade
36
General Comments17 - General Comment: Observed chair directly next to pool. Maintain 6 ft deck clearance. Immediate Suspension issued for #2 and #3. Once corrected, contact Katie at 704-309-5494 to re-open.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine at 0 ppm. Provide at least 1.0 ppm. Immediate Suspension issued.
3 6 Water quality: pool water pH No No No Observed pH at 7.0. Maintain at 7.2 to 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no log book. Provide log book. Record chlorine, pH and main drain check daily and cyanuric acid and alkalinity weekly. CPO must visit property one time per day.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed tile missing from pool wall. Replace.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed rope not connected to buoy. Corrected during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter stuck and pipe leaking from pump. Keep operational and repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed pump room left unlocked. Keep locked. Observed pump room floor wet and no cross/forced vent. Keep dry and provide ventilation.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap from backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed water >115 F in restroom. Maintain at 110 F or below.