Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOAK PARK AT NATIONS FORD APTS
Address103 DINADAN DRIVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/13/2017
Final Score @ Grade
34
General CommentsImmediate suspension issued for violation #6 and #15. Pool closed and gate locked. Contact Arlene Lawrence at 704-617-3068 when all items are corrected. NOTE: Remove plugs from inside skimmer leading into the pool or provide operable skimmers for the 2017 pool season. Observed all skimmers plugged on inside leading out into the pool. If you have any other questions you can contact Tim Dutcher, Supervisor over pools at 704-507-6808.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Maintain daily check of main drains and weekly checks of total alkalinity and cyanuric acid. Observed no recordings of daily main drain checks or weekly total alkalinity or cyanuric acid checks.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed Stingl Switch SR-500 system for single main drain not working. Power has been cut off to this system and a manual electric panel has been installed. Stingl Switch system needs to be repaired to work properly for an automatic shut off. (Immediate suspension issued).
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 2 out of 4 weirs missing from skimmers. Replace. Observed numerous amount of debris in skimmer baskets. Cleaned during inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed 2 rubber end caps missing on ladder. Replace
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed rope length on ring buoy at 39ft. Provide rope length at 50ft as required. (Immediate suspension issued).
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed some areas on chain link fence greater than 4 inches. Observed some areas of chain link fence where distance underneath was greater than 2 inches.
18 4 Premises: lifeguards present or warning signs posted No No No Observed "No-Lifeguard on Duty" sign that was posted had lettering less than 4 inches in height. Observed other warning signs with exact wording missing. CDI: all correct signage found in pump room and will be posted around pool.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter not working. Repair.