NameCHARLOTTE COUNTRY CLUB ADULT
Address2465 MECKLENBURG AVE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/10/2018
Final Score @ Grade
26
General Comments21. Pool will be required to post signage stating that this pool is NOT open for night swimming. CPO stated that easel will be placed next to pool with 'no night swimming sign' during night swimming at adjacent competition pool (C.Sells). Signage will be verified during night swimming lighting visit. *Pool is a type A pool less than 5 ft. deep, but CPO stated that lifeguards will be provided at pool. state and local permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. observed pH at 7.0. CDI to 7.2
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. observed missing weir. CDI .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. observed debris in skimmers. CDI
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. observed ground level door at teen room not self latching. observed windows without audible alarms. CDI alarms added to doors and windows. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. observed areas of pool enclosure < 48" in height (next to teen room) .2528(b) Horizontals shall not be located less than 45" in height. observed brick wall next to teen room with fence attachment on top at 36".
22 6 Premises: emergency telephone provided No No No .2530(a) Emergency phone shall remain operable. emergency phone not connected. CDI added phone.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. observed wet pump room floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. no directional flow on piping.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(k) Provide shatterproof mirrors. mirrors in restrooms are not shatterproof