8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers with build-up under basket. Keep clean. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed pool steps 25 ft witdth with only one handrail. Provide handrails every 10 ft or less for steps >20 ft. Repair fall 2014 for 2015 season. Provide letter documentation. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One return on steps without fitting. Replace. Pool replastered and will not fit. Adequate circulation provided. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Two pool lights rusted. Replace. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable. Repair for 2015 season. Provide documentation. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No cross/forced ventilation in chem storage. Provide. Lights burnt out in pump room. Replace. Bicarb on floor. Store up off floor. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Observed reciruculation pipes not clearly labeled. Clearly identify with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed 1 toilet/2 urinals and 1 toilet not operating. Sink leaking in women's. |