Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCEDARFIELD I
Address9468 STRATTON FARM RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/16/2014
Final Score @ Grade
26
General Comments6 - General Comment: (6) Aquastar 6" and (3) Waterways on skimmers. One equalizer line blocked/plastered. Resubmit PDSC before permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers with build-up under basket. Keep clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed pool steps 25 ft witdth with only one handrail. Provide handrails every 10 ft or less for steps >20 ft. Repair fall 2014 for 2015 season. Provide letter documentation.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return on steps without fitting. Replace. Pool replastered and will not fit. Adequate circulation provided.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Two pool lights rusted. Replace.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Repair for 2015 season. Provide documentation.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No cross/forced ventilation in chem storage. Provide. Lights burnt out in pump room. Replace. Bicarb on floor. Store up off floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Observed reciruculation pipes not clearly labeled. Clearly identify with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed 1 toilet/2 urinals and 1 toilet not operating. Sink leaking in women's.