NameJOHNSTON CREEK CROSSING
Address10310 CEDAR TRAIL LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/26/2022
Final Score @ Grade
16
General CommentsImages for in field pool verification of changes attached. Night swimming is not approved. Permit Restriction: flow meter must remain operable at 100 gpm +/- 5 % due to pipe and filter size restriction.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed leaves and flower debris in skimmers. CDI- CPO cleaned skimmers.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread. .2521 Install ladders per manufacturer instructions. - Observed ladders on 3 and 5 ft side without tread on top step. Observed ladder on 5Ft side in need of tightening down.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed buoy throw rope to be 44ft long. CDI- CPO provide rope at 38Ft.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Observed no forced or cross ventilation in chemical storage room.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed hose bibs near pool without proper back flow prevention devices.