| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. One out of three weirs missing. Replace. No permit action. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
10FT depth marker missing at deep end of inside of pool. Operator corrected and replaced. No permit action. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
.2523(e) Provide a minimum of a two inch wide contrasting color band across the pool bottom at breakpoint.
Breakpoint floor line fading/in poor repair. EHS recommends repainting. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Fitting missing from deep end of pool. Operator corrected and replaced. No permit action. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Two ring buoy ropes observed with too long ropes. Operator removed one and corrected the other to approved rope length. No permit action. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
EHS observed new looking knob less than 54” from the ground with openings greater than 1/2” surrounding it. Operator covered openings with chicken wire that satisfies the no greater than 1/2" within 18" of latch mechanism requirement. No permit action.
Gate hinge protrudes 4” on the outside from the fence and is less than 48” in height, creating a foothold. Outside knob protrudes 2.5” and is less than 40” in height, creating a foothold hold. Operator corrected by moving hinge higher than 48” and installing slanted metal piece above knob to mitigate foothold. No permit action. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed several cracks in deck with foliage growing through it. Deck is in need of repair to decrease any cracks. No permit action.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed 1” offsets on shallow end of pool deck. Operator grouted and corrected. No permit action. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
No sign indicating emergency phone on the outside of the phone. Operator corrected and posted emergency phone signage. No permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Pump room is not enclosed. Pool built in 1967. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. No air gap provided to discharged for backwashing. Pool built in 1967. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(j) Provide soap and soap dispenser, no glass, at each sink. There was not any soap present in both restrooms. |