10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. No safety top initially during arrival to inspection to show breakpoint in pool. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed ladder at a distance of 7 inches away from pool wall. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Decks in need of repair throughout.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Deck chairs within 6 ft walking space around pool. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. No pool signage present upon arrival to inspection. CDI- CPO provided appropriate signage during the inspection. |
|
19
|
4
|
Premises: signs prohibit glass containers or pets in pool area |
No |
No
|
No |
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area. No signs posted upon arrival to inspection. CDI- CPO provided during the inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals stored on the floor during the inspection.
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Pump room isn’t enclosed. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. No air gap provided to discharged for backwashing |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no shower sign posted upon arrival to inspection. CDI-Shower sign provided during the inspection. |