Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCAROLINA GOLF CLUB
Address2415 OLD STEELE CREEK RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/29/2020
Final Score @ Grade
20
General CommentsPermit issued for no night swimming. Diving board must remain inaccessible to the public until approved by the Department. Permit Restriction 1) Pool is required lifeguards during operating hours due to depth of pool. 2) Pool not approved for salt as primary chlorination. 3) Diving board not approved and must remain inaccessible. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain checks not recorded daily. Record daily.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No >25 ft between No Diving marker at divider line to shallow. Corrected/added during the inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2517 Diving equipment shall be installed in accordance with Rule .2517. Diving board not approved. Board is inaccessible to public currently with caution tape. Continue to keep inaccessible until approved by the Department.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No New fencing at wooden deck area. All other fencing is original except for latching mechanisms. Observed several locations with >4” between pickets and >2” under barrier at back gate and fence. Original construction. Maintain 4” or less between pickets and 2” or less under gate and fence. Maintenance gates swing into pool. If ever replaced, must be brought to current code and swing away from pool.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 8 ft. from pool edge throughout entire pool area. Maintain 8 ft. clearance around pool especially at diving area.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >118 F. Maintain at 110 F or below. Water heater turned down and bled during inspection.