Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCARMEL VILLAGE II
Address11056 RUNNING RIDGE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/23/2025
Final Score @ Grade
12
General CommentsOSV to pool for return construction and operating permit inspection. Pump room re-done in 2024 with new pump, filter and automated chemical controller. Plumbing re-run. Additional work done to repair the deck. Scope of Work - New waterline tile, plug EQ lines, new plaster, pavers on deck, re-bond pool around perimeter, new lights, damaged skimmers and piping replaced. Piping like for like. Skimmer replaced with Hayward SP1082. Viewed plumbing prior to covering. Renovation of deck by Stan Eaves. Renovation of pump room by Blue Fin Pools. New barrier installed by different contractor. Verified the following for equipment room. 1) Electrical permit for new pump - passed 4/3/2024. 2) New Pump - Hayward TristarVS HCP2500VSP, 2.7 THP. Flow at 92 gpm meeting permit restriction. 3) Blue white flow meter installed on 2" line with required inlet/outlet lengths. 4) Main drain, skimmer and return line - all 2" line. 5) ( 2) Aquastar A10RCFRxxx 2017 drain covers. 6) (4) Hayward SP1082 skimmers with EQ lines plugged in skimmer. Skimmers tied to 1.5" loop that T'sto 2" line back to pump room. Viewed during construction. 7) New Filter - Hayward HCF236. 8) 6 floor returns. Permit Restriction - Flow meter must remain operable. Flow required at 84 gpm to 101 gpm to meet turnover and flow restriction of suction pipe sizing. Flow greater than 119 gpm is suction hazard. Construction final passed. Permit issued for no night swimming with permit restriction above.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One floor return in deep end missing screw. 3 of 4 present. Install screw in return.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Barrier at front with 4" from ground to bottom of barrier at entry. Corrected during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some pool furniture <6 ft from pool edge. Maintain 6 ft. clearance around the pool in all locations.