NameCARMEL CROSSING TOWNHOMES
Address10995 CARMEL CROSSING DR
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/25/2023
Final Score @ Grade
36
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor and surface.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed some skimmers with debris present. CDI - skimmers emptied.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed several faded depth markers on pool deck. All illegible markers were corrected on site during inspection. Repair all fading depth markers and no diving markers by next pool season.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy and rope not in good condition. CDI - Ring buoy and rope replaced during inspection. Rope cut to required length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed several gaps < 1/2” within 18” of lock mechanism. CDI - Signage posted around lock blocking any gaps within 18”.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed cap mixing from opening in deck. CDI - Cap installed.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed wrong phone number listed on signage. CDI - Phone number corrected on sign during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter stuck and not operable. CDI - Flow meter was repaired on site.