8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace damaged skimmer lid. Observed skimmer lid during inspection. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Dearth markers are beginning to fade and need to be redone before next pool season. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.Observed ladder inside of the pool at 7 inches away from the pool wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 27 feet during the inspection. A need ring buoy rope was provided at a length of 30 feet., |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence bars bent producing openings approximately 6" across in two areas of perimeter fence. PIC corrected by bending bars back into original 4" width. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed deck with chipping and trip hazards at the deep side of pool. Repair before next pool season to prevent possible trip hazards. |