Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCARMEL CROSSING TOWNHOMES
Address10995 CARMEL CROSSING DR
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/29/2022
Final Score @ Grade
24
General CommentsPool not permitted for night swimming PDSC verified.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace damaged skimmer lid. Observed skimmer lid during inspection.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Dearth markers are beginning to fade and need to be redone before next pool season.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.Observed ladder inside of the pool at 7 inches away from the pool wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 27 feet during the inspection. A need ring buoy rope was provided at a length of 30 feet.,
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence bars bent producing openings approximately 6" across in two areas of perimeter fence. PIC corrected by bending bars back into original 4" width.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deck with chipping and trip hazards at the deep side of pool. Repair before next pool season to prevent possible trip hazards.