Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCAMBRIDGE ASSOCIATION
Address8501 CAMBRIDGE COMMONS DR
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/30/2026
Final Score @ Grade
26
General CommentsGC: Both pumps pull through the same set of main drains. Night Swimming is NOT permitted. Note: EHS observed warped fence posts at barrier fence. No warped fence posts created a greater than 4 inch gap on approach side of barrier; replace damaged fence posts as needed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed one (1) vacuum port in pool with no cover. CDI - CPO installed compliant cover for vacuum port.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed four (4) out of eleven missing weirs and five (5) seated tightly to prevent proper movement. Replace missing weirs and weirs that are unable to move freely. CDI - CPO installed and adjusted weirs such that six (6) of the eleven total were properly free floating and in place.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. .2521(b) Ladders shall have slip-resistant tread. Observed all ladders without slip resistant tread or safety caps at pinch points facing walls.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy ropes greater than permitted 50 ft. CDI - CPO measured ropes to 50 ft and cut them to the proper length.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed no functioning light in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. Observed one (1) urinal in male restroom non functioning with ‘Out of Order’ sign posted.