1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Water was too cloudy to see bottom of pool. Must be clear enough to see bottom of pool. |
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Cl was 0.4 ppm. Must be at least 1.0 ppm. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Vacuum port does not have a cover. Must have a cover for all fittings that could cause an entrapment. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy is no longer Coast Guard approved. Rope was observed at 29' must be 32' and at least 1/4" in diameter. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone did not have address and phone number posted. Must have address and phone number posted at emergency phone. Phone number is 704-536-7787 |