| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water > 110°F. Maintain at 110°F or less. |
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Cl 0ppm. Maintain at 1 ppm or greater. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records. Check daily Cl, pH, main drains. Check at least weekly total alkalinity and cyanuric acid. Left new sheet. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. Algae growing on pool walls. Keep cleaned. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some baskets full. Missing one weir, two weirs not functioning correctly. Provide functional weirs. Clean baskets on a regular basis. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope 30 feet long. Provide throw rope for ring buoy that is 32 feet long. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Latch < 54" high. Move latch such that it is at least 54" high. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and garbage cans too close to edge of pool. Maintain 6 feet clear walkway around pool and at least 5 feet around ladders and handrails.
Glass on ground within pool fence enclosure. Remove broken glass. |
|
19
|
4
|
Premises: signs prohibit glass containers or pets in pool area |
No |
No
|
No |
Provide signage stating no pets allowed. None observed. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Clean pump room / chemical storage room to provide access to equipment and chemicals.
Provide either forced air or cross-draft ventilation. Small vent in ceiling not large enough to allow for air movement. |