Premises Information

Return to Inspections
NameBRANTLEY OAKS SWIM CLUB
Address5108 WITHAM PASSAGE
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2026
Final Score @ Grade
26
General CommentsNight Swimming is NOT permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed one (1) vacuum fitting open during inspection. CDI - Vacuum cover was found and properly installed during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed minor debris from recent plastering on pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers from recent plaster construction. .2518(k) Replace missing weirs. Observed three (3) of eight skimmers with missing weirs. Replace as needed. Note: Four (4) installed weirs are minimally free flowing. Adjust weirs such that they are free flowing in skimmers.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy rope lengths greater than the permitted 50 feet. CDI - CPO adjusted rope lengths to required 50 feet after measuring. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. Observed only one (1) set of body hooks and ring buoy at start of inspection. CDI - CPO provided body hook and ring rope; hook and rope were properly attached to provided pole and ring buoy prior to end of inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed portions of pool deck wherein phone was not visible. CDI - Phone location was added to posted rules signage within pool deck. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect phone number at phone dialing instructions. CDI - Incorrect pool phone number was covered via tape at dialing instructions sign; proper pool phone number was written on tape.