Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBEVERLY WOODS EAST
Address3815 HUCKLEBERRY RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/1/2020
Final Score @ Grade
24
General CommentsScope of Work - Renovation of Restrooms and Pump room. No change to pool. Permit issued for no night swimming. Issuance of a permit by this department does not negate closure required by Executive Order No. 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order. Permit Restriction - Depth of pool requires lifeguards present at all times pool is operational. Jeff Gaeckle present during inspection. No signature due to Covid restrictions. Red phone signage added near vending machines that states location of emergency phone at front entry. Gate added to front entry to ensure fencing meets code requirements. Temporary meshing installed until permenant repair is made. Must meet code requirements with permanent repair. Note: No mirrors in restrooms. If installed, provide shatterproof mirrors. Note: No change to backwash line. Direct plumbed. Hose bibs for restrooms located on deck and outside of building with backflow prevention device. Pentair EQK1500, 15 hp with (2) SUNHPHxxx drain covers and (15) 6HPHAxxx EQ line covers.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Light by back 4 ft. area protruding from wall. Does not appear to be greater than 1/2". Continue to monitor and repair as needed to eliminate pinch hazard. Some etching on pool floor. Keep in good repair.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladder rungs >6" from wall to rung. Maintain 3" to 6" between ladder rung and wall. Slip-resistant tread beginning to wear off on diving board. Diving board missing labeling requirements. .2517(a)2 Provide installation instructions for diving equipment. .2517(a)4 Diving equipment shall be slip-resistant.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Blue hose bib outside of barrier provides foothold. Pool built pre-2010. Eliminate foothold.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Holes in deck where poles are placed for flags. While pool is operational to public, poles must be in place to elimiante offsets/openings of >1/2".
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at backwash line. Repair leak. Does not appear to affect circulation of system due to location on backwash line.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at backwash line. Keep pump room floor dry.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower sign not posted visible upon entry to pool. Corrected during inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilets in restrooms in need of cleaning. Keep fixtures clean.