Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539 Proper documentation of drain covers shall be submitted. Observed paramount covers on equalizers and not Aquastar A10RCFRxxx and Hayward pump that was 1.5 HP and not .5 HP as stated on PDSC form. Immediate suspension issued unitl approval given. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537 Pool walls and floors shall be kept clean and in good repair. Observed pool walls near surface where it was heavily cracked and portions of the wall is peeling away. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528 Gates must swing away from the pool unless natural topagraphy, landscape position, or emergency egress prevent gates from doing so. Observed gates that did not swing away from the pool. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537 Keep pool decks unobstructed and free of trip hazards. Observed wide spacing and cracks on pool deck. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534 Provide form of ventialtion in chemical room. Observed equipment/chemical room with no form of ventilation. |