Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir installed upside down. .2518(k) Provide functional weirs. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Service gates missing self-latching mechanism. .2528(a) All gates other than pedestrian access gates shall have a self-latching device. - Will need to correct by 2-28-2027.
Gate at bathrooms does not meet requirements. Door to bathrooms not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Will need to correct by 2-28-2027.
Gates with gaps > 2” under gate. .2528(a) Maintain 2" or less under gates. - Will need to correct by 2-28-2027.
Main gate with decorative cutouts and footholds. .2528(a) Where barrier consists of both horizontals and vertical members and horizontals are less than 45" apart, the horizontal member shall be located on the inside of the barrier with openings between vertical members no greater than 1.75 inches. - Will need to correct by 2-28-2027.
Decorative cutouts in pre-2010 fencing. .2528(b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010).
Pre-2010 fence with gaps > 4” under the fence. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 1, 2010). |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash plumbed directly into pump room floor. .2513(b) Filter backwash shall be discharged through an air gap. |