NameALPINE VILLAGE
Address4801 MONT BLANC DR
 
City/State/ZIP
CHARLOTTE NC 28227
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/13/2026
Final Score @ Grade
10
General CommentsInspection conducted with CPO Jenny Brink. Observed pre-permit items from previous inspection have been corrected. Facility has until February 28th, 2027 to correct noted issues with gates and door to restrooms. Can contact Will Harrison (704) 507-6824 to schedule inspection once issues have been corrected. Permit issued with the following conditions: No night swimming Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir installed upside down. .2518(k) Provide functional weirs. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Service gates missing self-latching mechanism. .2528(a) All gates other than pedestrian access gates shall have a self-latching device. - Will need to correct by 2-28-2027. Gate at bathrooms does not meet requirements. Door to bathrooms not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Will need to correct by 2-28-2027. Gates with gaps > 2” under gate. .2528(a) Maintain 2" or less under gates. - Will need to correct by 2-28-2027. Main gate with decorative cutouts and footholds. .2528(a) Where barrier consists of both horizontals and vertical members and horizontals are less than 45" apart, the horizontal member shall be located on the inside of the barrier with openings between vertical members no greater than 1.75 inches. - Will need to correct by 2-28-2027. Decorative cutouts in pre-2010 fencing. .2528(b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010). Pre-2010 fence with gaps > 4” under the fence. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 1, 2010).
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash plumbed directly into pump room floor. .2513(b) Filter backwash shall be discharged through an air gap.