2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.6 ppm. CDI - CPO corrected to 1.0 by the end of the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap between 2 two slats at the rear of the fence, measured at 6". CDI - CPO repaired and is now at 4".
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. bserved foot hold - railroad ties along exterior of the fence. Measured 35" for the top of the foot hold to the top of the fence. Pool - fence was built prior to 2010 |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed plastic white strips on the pool deck either missing or cracked. Observed cement with small hole about 1-2" on the deck along the backside of the 5ft area of the pool. Repair the hole and replace the plastic white strips. Will follow up on the repairs in 30 days. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on the hose bib. |