Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOPEWELL HIGH SCHOOL
Address11530 BEATTIES FORD RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type44 - School Building
CountyMecklenburg
Inspection Date 10/4/2017
Final Score @ Grade
91
General CommentsGeneral Comment: #4. Replace damaged toilet seat in girls bathroom on 700 hall. Clean toilet paper from ceiling in boys bathroom(900) building. #5. Repair spring loaded faucet fixture on hand washing sink in girls bathroom on 1st floor in 900 building. #8. Repair damaged seat in auditorium. Secure side cover on heating unit near exit door in 200 hall. Clean ventilation cover in 714. Replace blown light bulbs or replace light fixture in elevator in 900 building. #11. Repair underside of walkway covering leaving out from main school building near gym heading toward the 900 building. Observed section of walkway covering had already fallen and hanging and another section loosely hanging.*****REPAIR UNDERSIDE OF WALKWAY IMMEDIATELY!****Property manager(Susan Desoto) notified! Remove old boards/pallets from outside of gym area and 400 section of building. Provide covers for clean outs and remove protruding piping from grounds. Repair hand railing and boards on walkway leading to far back playground/soccer field. REMOVE DROP CORD RUNNING FROM ELECTRICAL OUTLET IN BOYS PE DRESSING ROOM INTO THE CEILING TO UNKNOWN LOCATION!

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 40 DRINKING FOUNTAINS: Clean and in good repair 40#; adequate pressure, properly regulated 40# (.2406) No No No Observed water fountains soiled throughout 700, 800, 500, 200, 300, 400 hall and 900 building. Thoroughly clean water fountains throughout school. Repair water fountains in back hallway of gym area near dressing rooms. Drinking fountains shall be kept clean and in good repair. 15A NCAC 18A .2406 (b).
6 15 FLOORS: WALLS: AND CEILINGS: Floors, walls, and ceilings clean and in good repair 30# (.2410) No No No Repair any and all roof or HVAC leaks; then replace water stained ceiling tiles in rooms throughout school building. Observed water stained ceiling tiles in 701, 714, 733,728, 854, 540, 200, 214, 311, 909, etc. Replace ceiling tiles in rooms with holes present. Clean ceiling in hallway area of 400 hall. Tightly secure loose transitional floor molding near entrance to gym area. Repair wall and damaged floor tile in chorus/band room storage room. Seal gap around window in chorus/band room. Address damaged floor tiles and gap along edge of flooring and wall in 410. Repair floor near exit door in chorus/band room. Secure loose transitional floor molding in auditorium. Clean carpet in media center. Patch hole in wall in 529. Floors, walls, and ceilings of all areas shall be kept clean and in good repair. 15A NCAC 18A .2410.
9 35 DRESSING ROOMS AND SHOWERS: Floors, walls, and ceilings clean, in good repair, washable, non-absorbent 30#; fixtures clean, in good repair 40#; facilities for storage of clothes provided, kept clean 20#; soap and towel 10* (.2413) No No No Thoroughly clean fixtures (hand washing sink, toilets, showers) in field house dressing rooms/and gym/PE dressing room. Repair wall in shower in outside field house dressing room. Repair ceiling in field house dressing room and gym/PE dressing room. Thoroughly clean water fountains in dressing rooms! Floors, walls, and ceilings of dressing rooms and showers shall be kept clean and in good repair. 15A NCAC 18A .2413 (a). All fixtures shall be kept clean and in good repair. 15A NCAC 18A .2413 (d).